- Overview
- Features
- Specifications
- Downloads
- Options & Accessories
The Powersoft Q4004 is a professional power amplifier designed to meet the most stringent requirements of professional users in concert touring, sound reinforcement and professional fixed installations.
Designed by Powersoft R&D team the Q4004 is exclusively built in Italy with internal components selected for premium quality and proven durability. Each modular subassembly is pre-tested, and the assembled Q4004 receives a rigorous 48 hours burn-in before through final check-out on precision test equipment for total quality control.
The Q4004 incorporates the legendary patented Powersoft universal switching mode power supply with Power Factor Correction providing users with worldwide AC acceptance and low consumption.
Powersoft bridgeable switch mode fixed frequency class D patented outputs provide high quality sound, excellent damping factor and cooler circuits for stable performances over time and longer amplifier life.
Optional sensing and communication board, on RS485 bus, provides full control and monitoring through proprietary software running on external PC, compatible with all other Powersoft Q, D, QTU and K Series amplifiers.
The Powersoft Q4004 is CE, UL and KETI approved.
- Powersoft legendary universal switch mode power supply with Power Factor Correction
- Fixed frequency switch mode output
- Patented output filter with ripple cancellation network
- Comprehensive front panel indicators
- Neutrik© Combo (XLR+Jack) balanced inputs and
- Speakon© outputs connectors
- Selectable HP, LP, BP filters and gate
- Fully protected circuit design with:
- AC protection: shut down power supply when AC mains voltage is outside operating range
- Clip limiter: prevents severely clipped waveforms from reaching loudspeakers, while still maintaining full peak power output
- DC protection: protects against infrasonic signal at the outputs
- VHF protections: protects the loudspeakers against non audible, strong, non musical very high frequency signals
- Short circuit protection: protects the amplifier from short circuit or other stressful events for the output circuits
- Thermal protection: when output rails reach 75°C (167°F) amplifier shut down outputs, they will unmute automatically when temperature will reach 65°C (149°F)
- Long term limiter: protects the loudspeaker against steady long term rms (non audio) signals reducing maximum output
- Temperature controlled continuous variable speed fan, front to back airflow
- Recessed stepped attenuators
- Detachable AC mains cable with IEC 16A socket
- Modular construction
| GENERAL |
|
|
|
|
|
Number of channels
|
4 |
|
|
|
|
| Output power |
2 Ω
|
4 Ω
|
8 Ω
|
4 Ω Bridged |
8 Ω Bridged |
| EIAJ test, 1 kHz, 1% THD |
n/a |
4 x 1,000 W |
4 x 600
|
n/a |
2 x 2,000 W |
| Max. output voltage |
98 V(peak) |
| AC MAINS POWER |
|
|
|
|
|
| Power supply |
Universal, regulated switch mode with PFC (Power Factor Correction) |
| Operating voltage |
115-230 V +15/-15%, 50/60 Hz, tolerant up to 400 V |
| Power factor cos (φ) |
>0.95 @ >200 W |
| Consumption / current draw |
|
@ 230 V |
@ 115 V |
| 1/8 of max. output power @ 4 Ω* |
625 VA |
3.4 A |
3.8 A |
| 1/4 of max. output power @ 4 Ω* |
1,250 VA |
6.1 A |
12.3 A |
| THERMAL |
|
|
|
|
|
| Environmental operating temperature |
0-45° C / 32-113° F |
| Thermal dissipation |
Fan, continuously variable speed, temperature controlled, front to rear airflow |
| Idle |
112 kcal/hr |
443 BTU/hr |
|
| 1/8 of max. output power @ 4 Ω* |
220 kcal/hr |
870 BTU/hr |
|
| 1/4 of max. output power @ 4 Ω* |
327 kcal/hr |
1,296 BTU/hr |
|
| AUDIO |
|
|
|
|
|
Gain (selectable via user menu)
|
32 dB |
|
|
|
| Input sensitivity @ 8 Ω |
1.73 V / 7.02 dBu |
|
|
|
| Input filters |
Internally selectable per channel: HP/LP/BP, 12 dB/oct, 65/100/130 Hz |
| Gate |
Internally selectable per channel: off/-50 dBu
|
| Input impedance |
10 kΩ |
|
|
|
| Frequency response |
5 Hz - 30 kHz (+/-3 dB) |
THD+N / SMPTE IMD
|
typ. <0.1% (<0.5% @ >0.1 W) |
| DIM100 IMD |
typ. <0.01% (<0.02% @ >0.1 W) |
| S/N ratio |
>105 dB(A) |
| Crosstalk separation |
>70 dB @ 1 kHz |
| Slew rate |
40 V/µs @ 8 Ω. input filter bypassed |
| Damping factor |
>600 @ 100 Hz |
| FRONT PANEL |
| Indicators |
5 LED′s per channel for output level: 3 x green, 1 x yellow, 1 x red 2 LED′s per channel: green for signal present (-66 dBV), red for protection 2 status LED′s: green for amplifier ready, yellow for thermal protection
|
| Controls |
1 stepped level attenuator pot per channel Power on/off switch |
| REAR PANEL |
| Input connectors |
2 x XLR Combo female, electronically balanced
|
| Output connectors |
2 x Speakon® NL4MD
|
| AC mains |
IEC C13 16 A (AC mains cord with 3-pin plug 15A for U.S., IEC ′Schuko′ 16A for else)
|
| Controls |
2 x link switch, linking inputs 1 & 2 and 3 & 4 |
Network data port RS485 (only "R" model)
|
1 x RJ45 with 2 x rotary address switches
|
| CONSTRUCTION |
| Dimension |
W 48.3 mm / 19", H 44.5 mm / 1U, D 455 mm / 17.9"
|
| Weight |
9.5 kg / 20.9 lbs |
| Side & rear reinforcement, front panel, dust covers |
5 mm steel |
| Top & bottom lid, rear panel |
1 mm steel |
* = With pink noise signal
Powersoft reserves the right to change specifications without notice.
(Power Factor Correction)
| Documentation:
|
Images:
- Q4004, front panel, lo res (134.91 kB)
- Q4004, rear panel, lo res (121.05 kB)
- Q4004, angle 1, lo res (151.44 kB)
- Q4004, angle 2, lo res (180 kB)
- Q4004, angle 3, lo res (147 kB)
- Q Series, stack, angle 1, lo res (417.1 kB)
- Q Series, stack, angle 2, lo res (438.33 kB)
|
|
 |
The Powersoft Power Control Hub is designed to meet the most stringent requirements of professional users in concert touring, sound reinforcement and professional fixed installations. The Power Control Hub incorporates an universal power supply able to provide users with worldwide AC acceptance.
|
 |
Armonía Pro Audio Suite is the new software for remote control and monitoring of Powersoft amplifiers: K Series, M DSP+ETH Series, D Series, Q Series, Duecanali and Ottocanali 1204 DSP+ETH. On-line or off-line system setup and tuning, real-time management and monitoring of all vital functions from a remote PC via a single intuitive graphical user interface. Learn more... |
- PC software for management of sound system including Powersoft amplifiers
- Compatible with Powersoft models of the following series: K, M*, Q**, D**, Ottocanali* and Duecanali. (* = requires "DSP+ETH" version / ** = requires "R" version)
Armonía Datasheet (929.39 kB) |
- Vastly extended features and functionality with DSP equipped amplifiers
- Faster, "real-time" communication and extended functionality with AESOP equipped amplifiers
|
|